Details
motor terminal board with mounting holes and fastening spigot (refer to image)
Suitable for electric motors from Siemens, Flender ATB Loher.
Important
The borespacing im Motor muss genau 20 mm betragen. A deviation can break the spigot on the terminal board.
scope of supply
scope of supply with nuts, connection washers according to DIN 46288, optionally without or with 3 bridges.
Dimensions in mm (refer to dimension sheet)
L | B | M | H | H | A | E | DØ | DØ | T |
54 | 34 | M5 | 13 | 19 | 20 | 20 | 9,5 | 5,3 | 8 |
Specifications
- bolt-Ø
- M5
- basic body
- 54 x 34 mm
- Hole spacing
- 20 mm
- permitted continuous current
- 25 A
- Nuts-tightening torque
- 2 Nm
- terminal designation
- W2-U2-V2
U1-V1-W1
Export-Info
- Customs tariff number
- 85030099
- Origin
- Deutschland
Manufacturers Info
Ing. Erich Geiss GmbH & Co. KG • Bahnstrasse 28 • 65843 Sulzbach • Deutschland • www.erichgeiss.de
Notes on delivery times1
The delivery time applies to deliveries to Germany.
Delivery times for other countries can be found at